Technical parameters

Number of functions:
Connection:
Voltage range:
Power input
(no operation / make):
Supply voltage tolerance:
Time ranges:
Time setting:
Time deviation:
Repeat accuracy:
Temperature coeffi cient:
Output
Number of contacts:
Resistive load:
Inductive load:
Control
Control voltage:
Control current:
Impulse length:
Glow tubes connetions:
Max. amount of glow lamps
connected to controlling
input:

Other information

Operating temperature:
Operating position:
Mounting:
Protection degree:
Overvoltage category:
Pollution degree:
Fuse:
Connection wires
3x CY, 0.75 mm
(cross-section / lenght):
Glow-lamps in control button:
Dimensions:
Weight:
Standards:
Warning
Device is constructed for connection in 1-phase main AC and must be installed according to norms valid in the state of application.
Connection according to the details in this direction. Installation, connection, setting and servicing should be installed by qualifi ed
electrician staff only, who has learnt these instruction and functions of the device. This device contains protection against over-
voltage peaks and disturbancies in supply. For correct function of the protection of this device there must be suitable protections
of higher degree (A, B, C) installed in front of them. According to standards elimination of disturbancies must be ensured. Before
installation the main switch must be in position "OFF" and the device should be de-energized. Don´t install the device to sources of
excessive electro-magnetic interference. By correct installation ensure ideal air circulation so in case of permanent operation and
higher ambient temperature the maximal operating temperature of the device is not exceeded. For installation and setting use
screw-driver cca 2 mm. The device is fully-electronic - installation should be carried out according to this fact. Non-problematic
function depends also on the way of transportation, storing and handling. In case of any signs of destruction, deformation, non-
function or missing part, don´t install and claim at your seller. After stop using the product it is possible to demount and recycle.
SMR-K
SMR-T
9
3-wire, without neutral
AC 230 V / 50 - 60 Hz
0.8 / 3 VA
10 % - mechanical setting
2 % - set value stability
0.1 % / °C, at = 20 °C (0.1 % / °F, at = 68°F)
1x triac
10 - 160 VA
10 - 100 VA
AC 230 V
25 μA
min. 50 ms / max. unlimited
x
x
(measured with glow lamp 0.68 mA / 230 V AC)
0.. 50 °C (32.. 122 °F)
free at connecting wires
IP30 in standard conditions
F 1A / 250 V
2
(AWG 18) /
4x CY, 0.75 mm
90 mm (3.5˝)
x
49 x 49 x 13 mm (1.9 x 1.9 x 0.5")
26 g (0.9 oz)
26 g (0.9 oz)
EN 61812-1, EN 61010-1
SMR-H
4-wire, with neutral
-15 %; +10 %
0.1 s - 10 days
via rotaty switch
0 - 200 VA
0 - 100 VA
8 A 250 V AC (cos φ > 0.4)
3 mA
Yes
230 V - max. amount 50 pcs
any
III.
2
2
(AWG 18 )/
2x CY, 0.75 mm
90 mm (3.5˝)
2.5 mm
max. 10
49 x 49 x 21 mm (1.9 x 1.9 x 0.8")
27 g (1 oz)
2 / 2
Function
SMR-B
10
a) Delay off on entrering edge - Output times
when it is switched. Each following pressing
(max. 5x) increases timelong pressing swithes
output off .
max. 1 / 1 VA
b) Delay off on descending edge - after a switch
is pushed, output switches immediately, starts
timing after a button is released.
1x NO / SPST (AgSnO
)
2
16 A 125 / 250 V AC1
c) Delay off on descending edge - output switches
and starts timing after a buttonis released.
AC 230 V,
UNI - 5-250 V AC/DC
d) Cycler - fl asher - Output regularly switchesac-
cording to set intervals.
e) Impulse shift - Delayed switching after push-
ing a switch and delayed switching off after its
release.
x
2
(AWG 18), 2x CY,
2
(AWG 10) / 90 mm (3.5˝)
max. 20
f ) Delay on - Output switches with delay after
switch on, this state stays until the product
53 g (1.9 oz)
doesnt switch off .
g) Impuls relay - After energization by pressing
a button, output switches, and switches off by
another pressing. The length of pressing does
not matter. Delay for reaction to a button can be
set by potentiometer and thus eliminate button
contact recoil.
h) Impulse relay with delay - When pressing a but-
ton, output switches and starts timing. Another
pressing switches the output off in case it hap-
pens before timing is fi nished.
i) Cycler starting with a gap - Output cycles in reg-
ular intervals, cycler starts with a gap.
j) Cycler starting with gap - Delay on after switch-
ing on until it is de-energized or a switch is
pressed again (function j is valid only for SMR-B).
S
>2 s
a
V
t
2x t
S
b
t
V
S
c
V
t
S
d
V
t
t
t
t t
S
e
t
t
V
S
f
V
t
S
g
V
t
t
S
h
V
t
S
i
V
t
t
t
t
t
t
S
j
V
t
t

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Smr-tSmr-hSmr-b

Tabla de contenido