2.4 Grips
Vibration-absorbing grip
2.5 Lubrication
Oil lubrication
2.6 Items supplied as standard
1 Power tool
1 TE C or TE T chuck
1 Operating instructions
1 Hilti toolbox
1 Cleaning cloth
1 Grease

2.7 Using extension cords

Use only extension cords of a type approved for the application and with conductors of adequate cross section.
The power tool may otherwise loose performance and the extension cord may overheat. Check the extension
cord for damage at regular intervals. Replace damaged extension cords.
Recommended minimum conductor cross section and max. cable lengths
Conductor cross
1.5 mm
section
Mains voltage
100V
Mains voltage
20 m
110-120 V
Mains voltage
50 m
220-240 V
Do not use extension cords with 1.25 mm or 16 AWG conductor cross sections.
2.8 Using extension cords outdoors
When working outdoors, use only extension cords that are approved and correspondingly marked for this
application.
2.9 Using a generator or transformer
This power tool may be powered by a generator or transformer which fulfills the following conditions: The unit
must provide a power output in watts of at least twice the value printed on the rating plate on the power tool.
The operating voltage must remain within +5% and -15% of the rated voltage at all times, frequency must be in
the 50 – 60 Hz range and never above 65 Hz, and the unit must be equipped with automatic voltage regulation
and starting boost.
Never operate other power tools or appliances from the generator or transformer at the same time. Switching
other power tools or appliances on and off may cause undervoltage and / or overvoltage peaks, resulting in
damage to the power tool.