3.2 Testing the Cable
3.2.1
Unscrew the two screws holding the front
top cover in place, and remove the cover.
Note: Some models may differ slightly in shape,
color, etc.
3.2.3
Remove the cable from the motor unit,
and unplug the cable.
on
3.2.5
Switch the power supply on.
If the tester light is on ( ), proceed to test the
terminal.
4
3.2.2
Open the clip that holds the cable in place
and remove the cable.
2
1
3.2.4
Connect the cable to the power supply (1)
and tester (2).
oFF
3.2.6
If the tester light is off ( ), repair or replace
the cable.
Dolphin Service Kit
|
User Instructions