Sammic AG-20 Manual De Instrucciones página 9

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 1
that the thermocouple is working pro-
perly and is well screwed.
4. Face grid: It has to be changed when
there are holes or it is deformed or bro-
ken, so interrupt the cooking process.
5. Motor: It has to be changed when you
notice a malfunction on the rotation or
there is no rotation at all, although the
rest of the electric circuit is correct.
6. Motor switch: It has to be changed when
you notice a malfunction when you press
it, or when the motor does not tern at
all, although the rest of the electric cir-
cuit is correct.
7. Electric circuit cables: The cable of the
electric circuit that connects the motor
with the motor switch and pass over hot
arias of the appliance, must be changed
every year. The rest of the cables must
be checked often for their proper condi-
tion.
8. Supply Cable: If the supply cable is
damaged, it should be substituted by
the manufacturer, by its authorized ser-
vice or by similar qualified personal with
the objective to avoid a danger.
Attention: Only specialized technicians
should make the above cases.
OTHER IMPORTANT COMMENTS
- This machine is not designed to be used
by individuals (including children) with
reduced physical, sensorial or mental
facilities, or who lack the relevant expe-
rience or knowledge, unless they are
supervised by or have received instruc-
tion on how to use the apparatus from a
person responsible for their safety.
EN
9

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ag-30Ag-40

Tabla de contenido