4
Technical specifications
Type CDVI5.0−...
Dimensions
Number of valve locations
Control voltage
Rated value (protected against
incorrect polarity)
Tolerance
Total permitted current
Protection class as per EN 60529
Temperature ranges/storage duration
Ambient/medium temperature
Storage temperature
Recommended storage duration
Materials
Electromagnetic compatibility
Interference emitted
Immunity to interference
1)
The CDVI valve terminal is intended for industrial usage.
2)
The maximum permitted signal cable length is 10 m.
14
See Pneumatics manual
4, 6, 8, 10, 12
24 V DC
± 10 % (21.6...26.4 V DC)
1992 mA
IP65 and IP67
(fitted completely)
− 5 ... + 50 °C
− 20 ... + 40
Max. 18 months
See Pneumatics manual
Tested as per EN 61000−6−4
(industry)
2)
Tested as per EN 61000−6−2
(industry)
°
C
1)
Festo CDVI... 0302a English