5. Electrical connection (see appendix) (GIBE).
Hazardous Voltage
WARNING
Contact may cause electric shock or burn.
The machine is not equipped with a mains plug and must be connected to the power supply. The elec-
trical connection, which is to be provided by customer, must be carried out by a qualified electrician.
Observe mains voltage: The mains voltage and the frequency of the power source must agree with
the data on the type plate of the machine.
Plug the mains plug of the extraction system into the intended socket outlet on the machine.
6. Intended use of the machine.
The undercarriage is intended for stationary mounting of GRIT GI 75/150 stationary belt grinders.
7. Adjustments GIB (Figure 5).
Loosen both clamping levers. Adjust the
machine to the required working height.
Tighten both clamping levers again.
8. Operating instructions (GIBE).
8.1 Switching ON and OFF (GIBE)
The extraction system is automatically switched
on or off via the On/Off switch of the mounted
machine.