SILVER 24T - 34T
Con-
Description
Range
tents
Heating post-circu-
P05
0-255minutes
lation
P06
Pump operation
0-7=Operation strategy
Modulating pump
P07
0-100%
min. speed
Modulating pump
P08
0-100%
start speed
Modulating pump
P09
0-100%
max. speed
Pump deactivation
temperature during
0-100°C
Post-Circulation
(b02=1)
Pump deactivation
temperature during
0-100°C
Post-Circulation
(b02=2)
P10
Pump deactivation
temperature during
0-100°C
Post-Circulation
(b02=3)
Pump deactivation
temperature during
0-100°C
Post-Circulation
(b02=4)
Pump activation
hysteresis tempera-
0-100°C
ture during Post-Cir-
culation (b02=1)
Pump activation
hysteresis tempera-
0-100°C
ture during Post-Cir-
culation (b02=2)
P11
Pump activation
hysteresis tempera-
0-100°C
ture during Post-Cir-
culation (b02=3)
Pump activation
hysteresis tempera-
0-100°C
ture during Post-Cir-
culation (b02=4)
Heating user max.
P12
20-90°C
set point
Max. output in heat-
P13
0-100%
ing
0=Fixed
1=Linked to set point
Burner shutdown in
hot water production
2=Solar (5)
(b02=1)
3=Solar (10)
4=Solar (20)
Legionella protec-
0-7=Activation days
tion (b02=2)
P14
Burner shutdown in
0=Fixed
DHW (b02=3)
1=Linked to set point
2=Solar (5)
3=Solar (10)
4=Solar (20)
Legionella protec-
0-7=Activation days
tion (b02=4)
Comfort activation
temperature
0-50°C
(b02=1)
Hot water tank hys-
0-60°C
teresis (b02=2)
P15
Comfort activation
temperature
0-80°C
(b02=3)
Hot water tank hys-
0-60°C
teresis (b02=4)
Not used (b02=1)
Do not modify
Primary set point
70-85°C
(b02=2)
Comfort deactiva-
P16
tion hysteresis
0-20°C
(b02=3)
Primary set point
70-85°C
(b02=4)
Default
SILVER 24T
SILVER 34T
15minutes 15minutes
15minutes
0
4
4
30%
30%
30%
75%
75%
75%
100%
100%
100%
50°C
20°C
20°C
20°C
33°C
20°C
10°C
5°C
5°C
5°C
47°C
5°C
80°C
80°C
80°C
80%
80%
80%
0=Fixed
0=No prot. 0=No prot.
0=No prot.
0=Fixed
0=No prot.
40°C
2°C
2°C
2°C
40°C
2°C
7
80°C
80°C
80°C
20°C
80°C
cod. 3541I691 - Rev. 00 - 01/2017
Con-
Description
Range
tents
P17
DHW standby time
30-255seconds
(b02=1)
No effect on adjust-
30-255seconds
ment (b02=2)
DHW standby time
30-255seconds
(b02=3)
No effect on adjust-
30-255seconds
ment (b02=4)
P18
DHW user max. set
40-70°C
point (b02=1)
DHW user max. set
40-70°C
point (b02=2)
DHW user max. set
40-70°C
point (b02=3)
DHW user max. set
40-70°C
point (b02=4)
P19
DHW pump Post-
0-255seconds
Circulation (b02=1)
DHW pump Post-
0-255seconds
Circulation (b02=2)
DHW pump Post-
0-255seconds
Circulation (b02=3)
DHW pump Post-
0-255seconds
Circulation (b02=4)
P20
Max. output in DHW 0-100%
P21
Comfort1 standby
0-100minutes
time (b02=1)
Not implemented
--
(b02=2)
Not implemented
--
(b02=3)
Not implemented
--
(b02=4)
P22
Comfort2 standby
0-100minutes
time (b02=1)
Not implemented
--
(b02=2)
Not implemented
--
(b02=3)
Not implemented
--
(b02=4)
P23
Fan frequency in
0-70Hz
standby mode
P24
Post-Ventilation
0-120seconds
P25
Modulating pump
0-60°C
adjustment temper-
ature (b02=1)
Modulating pump
0-60°C
adjustment temper-
ature (b02=2)
Modulating pump
0-60°C
adjustment temper-
ature (b02=3)
Modulating pump
0-60°C
adjustment temper-
ature (b02=4)
P26
Primary exchanger
0-150°C
protection tempera-
ture (b02=1)
Primary exchanger
0-150°C
protection tempera-
ture (b02=2)
Primary exchanger
0-150°C
protection tempera-
ture (b02=3)
Primary exchanger
0-150°C
protection tempera-
ture (b02=4)
P27
System min. pres-
0-8 bar/10
sure value
P28
System nominal
5-20bar/10
pressure value
P29
Exchanger protec-
0=No F43
tion intervention
1-15=1-15°C/second
(b02=1)
Not implemented
--
(b02=2)
Exchanger protec-
0=No F43
tion intervention
1-15=1-15°C/second
(b02=3)
Not implemented
--
(b02=4)
Default
SILVER 24T
SILVER 34T
120second
s
120second
120seconds
120seconds
s
120second
s
120second
s
55°C
65°C
65°C
65°C
55°C
65°C
0seconds
30seconds 30seconds
30seconds
30seconds
30seconds
100%
100%
100%
20minutes
--
--
--
--
--
42minutes
--
--
--
--
--
0Hz
0Hz
0Hz
30seconds 30seconds
30seconds
18°C
18°C
18°C
18°C
18°C
18°C
35°C
150°C
150°C
150°C
35°C
35°C
4 bar/10
4 bar/10
4 bar/10
7 bar/10
7 bar/10
7 bar/10
10°C/sec-
ond
--
--
--
10°C/sec-
ond
--
EN
25