STEP 1
INSTALLATION OF THE PUMP IN THE PIT
1.1)
Refer to Figure 1.1 for a typical pump installation.
STEP 2
INSTALLATION OF THE VARIABLE LEVEL FLOAT SWITCH
2.1) Install the float attachment
clamp as shown in Detail A.
IMPORTANT! DO NOT
INSTALL SWITCH CORD
UNDER HOSE CLAMP
2.2)
Set the pumping range
according to Chart A and
Figure 2.2.
2.3)
Secure the hose clamp to
the discharge pipe.
DETAIL A
DETAIL "A"
IMPORTANT! TETHER
LENGTH CANNOT BE
LESS THAN 4" (10 CM).
Figure 1.1
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
1
2
3
MIN. TETHER LENGTH
4" (10 cm)
MIN.
SK2067A
IMPORTANT! **SECURE THE PUMP POWER
CORD TO THE DISCHARGE PIPE AS SHOWN IN
FIGURE 2.2. CORD SHOULD BE AT OR ABOVE
THE PUMP "ON" LEVEL.
© Copyright 2015 Zoeller
PROPERLY GROUNDED CIRCUIT
CHECK VALVE
VENT PIPE
WEEP HOLE
SECURE CORD
TO PIPE
DISCHARGE
PIPE
PUMP
CHART A
4
5
6
7
8
9 10 11 12 13 14 15
16
17
TETHER LENGTH (INCHES)
(DIMENSION "B")
Co. All rights reserved.
®
3
(typical installation)
(GFCI)
COVER
SK2065
Tether "B"
Range "A"
4" (10.2 cm)
6.5" (16.5 cm)
6" (15.2 cm)
8" (20.3 cm)
8" (20.3 cm)
10.5" (26.7 cm)
10" (25.4 cm)
14" (35.6 cm)
12" (30.5 cm)
18" (45.7 cm)
14" (35.6 cm)
22" (55.9 cm)
16" (40.6 cm) 26" (66.0 cm)
SK2175
Figure 2.2
B
A
"ON"
LEVEL
"OFF"
LEVEL
SK2067B