DESCRIPTION
This portable utility pump is designed to be used as a transfer pump for such
applications as emptyingwater heaters, swimmingpools, livestock tanks, boats,
etc. Pump can also be used for an intermittent pressure booster for applications
suchas washingcars, cleaningdriveways, etc. Themotor is air cooled. It is NOT
designed to operate under water.
INSTALLATION
Always disconnect power source before
attempting to install, service or maintain the pump. Never handle a pump
with wet hands or when standing on wet or damp surface or in water.
Fatal electrical shock could occur.
1. Aground fault circuit interrupter (GFCI) is recommended.
Risk of electrical shock. This pump is supplied
withagroundingconductorandgroundingtypeattachmentplug.Agrounded
receptaclein conformancewith current NECand local codes must beused.
2. This pump operates on 115V , 60Hz AC, single phase.
Risk of fatal electrical shock. Never cut off the
round grounding prong. Cutting the cord or plug will void the warranty
and make the pump inoperable.
3. Figure 1 shows a typical installation. Threaded adapters are furnished for
attaching garden hosewhereconditions permit its use. Innocase shouldthe
pumpbemorethan15feet aboveor away frominlet source. Useof foot valve
on inlet line is recommended.
IMPORTANT : Make sure the inlet hose is NOT coiled or kinked above or
below water level.
15 Ft. Inlet Line Length Max.
IN
OUT
IL0123
Figure 1
4. The inlet line may be galvanized pipe, plastic pipe, or non-collapsible hose.
OPERATION
IMPORTANT : Pump must be ¿lled with water before operation. Running
the pump dry or pumping any sand or other abrasives will cause damage
to the shaft seal or impeller and void the warranty.
1.
permanently installed outdoors. If installed outdoors, care should be taken to
protect the unit from rain and other elements of the weather. This unit is not
waterprooforweatherproofandisnotintendedtobeusedinshowers,saunas,
or other potentiallywet locations. Themotor isdesignedtobeusedinaclean,
drylocationwithaccesstoadequatecoolingair.Ambient temperaturearound
the motor should not exceed 104 ° F (40 ° C).
2. Remove priming plug and ¿ll with water. Reinstall plug.
IMPORTANT : To help with the priming of the pump, a foot valve can
be installed on the suction line. The use of a foot valve is strongly
recommended to be installed on inlet lines lifting over ¿ve feet.
3. Plug power cord into GFCI protected electrical outlet. Thepump will prime in
a few minutes, depending on inlet line length.
IMPORTANT : To avoid internal pump damage, if after ¿ve minutes the
pump has not begun pumping water, turn off the pump, remove the
priming plug, re-¿ll pump with water, reinstall priming plug and plug
pump back in.
4. In the case of pressure boosting, turn water on before starting pump. This
force primes the pump. Then, plug power cord into GFCI protected electrical
outlet.
MAINTENANCE
to service. Motor may be extremely hot. Personal injury may result.
1. Pump should be checked periodically for proper operation.
before attempting to install, service, or perform any maintenance. If the
power source is out of sight, lock and tag in the open (off) position to
prevent unexpected power applications. Disconnect electrical cord from
power supply. Failure to do so could result in fatal electrical shock. Only
quali¿ed electricians should repair this unit. Improper repair could result
in fatal electrical shock.
BRUSHREPLACEMENT
Fill with
water
IMPORTANT : Brushes for this pump should be inspected after every 100
hours of operation.
Product is portable, and not intended to be
Let pump cool for at least 20 minutes before attempting
Always disconnect the electrical supply