NOTE
Recommended tightening torque (blade): 33-37 Nm.
5.1

GENERAL MAINTENANCE

Before each use, examine the machine for damaged,
missing, or loose parts such as screws, nuts, bolts and
caps.
Tighten correctly all the fasteners and caps.
Clean the machine with a dry cloth. Do not use water.
5.2

REPLACE THE BLADE

Figure 11
WARNING
Use only approved replacement blades.
WARNING
Wear heavy gloves or wind cloth around the blade when
you touch the blade.
1. Stop the machine.
2. Make sure that the blades fully stop.
3. Remove the safety key and battery pack.
4. Turn the machine to its side.
5. Use a piece of wood to prevent the movement of the
blade.
6. Remove the mounting screw with a wrench or socket.
7. Remove the blade.
8. Install the new blade. Make sure that the arrows engage
the holes in the blade.
9. Put in the mounting screw and tighten it.
5.3

STORE THE MACHINE

Clean the machine before storage.
Make sure the motor is not hot when you store the
machine.
Make sure that the machine does not have loose or
damaged parts. If it is necessary, do these steps/
instructions:
Replace the damaged parts.
Tighten the bolts.
Speak to a person at an approved service center.
Store the machine in a dry area.
Make sure that children cannot come near the machine.
6

TROUBLESHOOTING

Problem
The handle is not in position.
English
Possible cause
The bolts are not engaged correctly.
7
Solution
Adjust the height of the handle and make
sure that the knobs and bolts are aligned
correctly.
EN