INSTALLATION INSTRUCTIONS
Synthesized Intelligent PIR
Synthesized Intelligent PIR
REDWALL-V series
REDWALL-V series
FEATURES
* Intelligent PIR Detection System
- Three dual pyro-elements with patented Double Conductive
Shielding
- Detection of ambient temperature and illuminance for
automatic sensitivity management
- Advanced detection algorithm
* Anti-vandalism functions
- Max.4 m (13 ft.) installation height
- Anti-rotation with 3-axis accelerometer
- Anti-masking with photo-beam
* Sensitivity selector for near/far area independently
* Detection logic selector
* Detection range selector
* Independent N.C. and N.O. ALARM output
* Adjustable alarm interval time
* Reinforced polycarbonate housing
REDWALL-V
: Synthesized Intelligent PIR
•
SIP-3020
•
SIP-4010
•
SIP-404
1
PARTS IDENTIFICATION
Base
Main unit
Fixing screw
for the base
Adjustment screws
(two facing each other)
Angle adjustment guide
Arrow marking
Fixing screw
NO.5914940
REDWATCH-V
: Synthesized Intelligent PIR
with D/N camera
•
SIP-3020CAM DN (EU)
•
SIP-3020CAM DN (US)
Far area mirror
Masking plate for far area
Fixing rubber form
Window
Fixing rubber
Fixing screw
form (*1)
for the cover
Masking plate for near
Cover
area (*1)
Near area mirror
*1: Not used for the SIP-4010 and SIP-404.
SIP-3020CAM DN
Camera unit
2
INSTALLATION AND MAINTENANCE NOTES
Warning
Never repair or
modify product
Nylon wire
loop
When servicing, the sensor
can be hooked onto the
base using the nylon wire
loop.
2-1
INSTALLATION HINTS
2.3-4.0 m
(7.6-13 ft.)
Mount the detector so that the majority of traf¿ c À ow is across the detection pattern.
- 1 -
Caution
Hold the main unit
securely when you
install or service it.
If you remove your
hands from the main
unit when cables are
connected to it, the
main unit may fall
and the connector
cables may break
or the circuit board
may be damaged.
Caution
Verify that the
power is off before
connecting the
wiring.