Power wires should not exceed the following lengths.
SIP-3020/SIP-4010/SIP-404
WIRE
GAUGE
12V DC
14V DC
2
0.33 mm
580
770
(AWG22)
(1900)
(2530)
2
0.52 mm
910
1210
(AWG20)
(2990)
(3970)
0.83 mm
2
1450
1930
(AWG18)
(4760)
(6330)
4
DETECTION AREA SETTING
You can adjust the detection area by 90 degrees in a horizontal
direction and by 10 degrees in a vertical direction.
Correct the vertical detection angle according to the mounting
height of the sensor unit.
Applicable
SIP-3020 SIP-4010
models
90°
Applicable
SIP-3020 SIP-4010
models
90°
Cautions>>
To rotate the main unit counterclockwise, loosen the
RHside adjustment screw. To rotate the main unit
clockwise, loosen the LH-side adjustment screw.
Otherwise, you may find it difficult to tighten or you may
find that you cannot tighten the adjustment screw when
you are securing the main unit.
To rotate the unit counterclockwise
SIP-3020CAM DN (EU)
SIP-3020CAM DN (US)
24V AC
12V DC
1370
100
(4490)
(330)
2160
160
(7090)
(520)
3450
250
(11320)
(820)
SIP-404
SIP-3020CAM DN
SIP-3020CAM D
10°
10°
90°
SIP-404
SIP-3020CAM DN
10°
90°
10°
Adjustment
screw
To rotate the unit clockwise
(1)
Adjust the angle of the main unit in a horizontal direction so
that you can cover the desired detection area.
m (ft.)
1
Loosen the ¿ xing screw for
the base.
(2)
Adjust the angle of the main unit in a vertical direction so
that you can cover the desired detection area.
Cautions>>
If the mounting wall is at an angle, the arrow of the
main unit may exceed the top or bottom limit of "Angle
adjustment guide". Always check this using the area
viewfinder or the walk tester. If the detection area is
too high or too low, an object outside the detection
area may be detected or incorrect object detection may
occur.
(3)
Remove the cover.
Cautions>>
The cover is linked to the main unit by nylon wire loop so
that the cover does not fall. Do not pull the cover using
excessive force.
- 3 -
3
Rotate the main unit.
2
Loosen the adjustment screw.
4
Tighten the adjustment screw slightly.
Align the arrow of the main
unit with the "Angle adjustment
guide" of the adjustment
screw. The main unit is usually
adjusted within the width of this
guide.
When mounted
at a height of
2.3 meters
(7.6ft.)
When mounted at a
height of 4.0 meters (13ft.)
Hooks
3
Slide the cover downward
and release the hooks.
1
Loosen two ¿ xing screws for
the cover and pull out the
cover until it stops.
Cover
2
Hold the heads of both cover ¿ xing screws with your
hands, and pull down and remove the bottom section
of the cover from the main unit.