28 | TCE 5310 - TCE 5320 | Adjustments
short-circuited. Rare, but in any case possible, check the electromagnetic coils of the electrovalves or the micro
switches on the pedal box that can short-circuit if damaged.
3.8.6

F7 - protection fuse of the 24VAC circuit

In case it blows check that the connection cable of the pedal box is not damaged and that the cables inside are
not interrupted or short-circuited, and that the micro switches on the pedal box are not short-circuited if they are
damaged. Finally, check also the two remote control switches of the rotation mandrel, specially the coils.
!
With this type of single-phase machinery be very careful when operating on the motor condensers, since they
retain for a long time the residual electrical charge, and therefore subsists the danger of electrical discharges of
considerable intensity if they are inadvertently touched.
|