Troubleshooting; Tank Inspection; Product Parts Information - IRT N2 Serie Información De Instalación Y Mantenimiento

Sistema de llenado de neumáticos de nitrógeno
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

EN
Trouble Shooting
Error
Delivery of nitrogen too low
or absent
System does not
automatically switch off
Maintenance Kit
Part
Primary Filters (both required to service filters)
Contracted Maintenance Instructions
(To be performed by Authorized Ingersoll-Rand Technicians. Call 1-866-NSP-Serv [1-866-677-7378])
Part
Carbon Absorber
Oxygen Analyzer
Tank

Tank Inspection

(To be performed by Authorized Ingersoll-Rand Technicians. Call 1-866-NSP-Serv [1-866-677-7378])
The life of a nitrogen receiver tank is dependent upon several
factors including, but not limited to, operating conditions,
ambient environments, and the level of maintenance. The
exact effect of these factors on tank life is difficult to predict,
therefore, Ingersoll-Rand recommends that you schedule a
certified tank inspection within the first five years of system
service. Additional inspections should be done every 5 years.
If the tank has not been inspected within the first 10 years of
service, the tank must be taken out of service until it has
passed inspection. Tanks that fail to meet requirements must
be replaced.

Product Parts Information

The use of other than genuine Ingersoll-Rand replacement parts may result in safety hazards, decreased product
performance, and increased maintenance and may invalidate all warranties.
Repairs should be made only by authorized trained personnel. Consult your nearest Ingersoll-Rand Authorized
Servicenter.
The original language of this manual is English.
Manuals can be downloaded from www.irtools.com
Refer all communications to the nearest Ingersoll-Rand Office or Distributor.
EN-5
Possible Cause
Compressed air supply too low
Ambient temperature is too high
Compressed air temperature is too high
Air filters are polluted
Leak in piping
Automatic drain is continuously open
Nitrogen outlet line is blocked.
Blockage
Inlet air pressure too low
Pressure switch setting
Leak in piping
Nitrogen outlet is open
Automatic drain is continuously open
Action
Replace carbon.
Replace analyzer.
Inspection
CAUTION
Possible Solution
Check / increase the air supply pressure
Lower the temperature, if possible
Lower the temperature, if possible
Change or clean the air filters
Check for leaks in the piping.
Check the automatic drain for leaks.
Check / open the outlet line
Check the compressed air delivery to the
compressor
Increase inlet air pressure
Check pressure switch settings. (Consult your
nearest Authorized Servicenter.)
Check for leaks in the piping.
Close outlet
Check the automatic drain.
Part No.
15249634 and 15249618
Frequency
18 months, together with the filter
elements
18 months
5 years, or if any damage occurs to tank
CAUTION
Failure to replace a rusted air receiver tank could result
in air receiver tank rupture or explosion, which could
cause substantial property damage, severe personal
injury, or death. Never modify or repair tank. Obtain
replacement from Service Center.
When life of the product has expired, it is recommended that
the product be disassembled, degreased and parts be
separated by materials that they can be recycled.
15255342_ed2

Publicidad

Tabla de contenido
loading

Tabla de contenido