CONTROL PANEL

B
A
Make sure to open the louver (#2) before using.
Power Control (A)
The power control turns the unit on and off. After switching the air conditioner off, you must wait 3
minutes before switching it back on again.
Warning Light "FULL " (B)
Condensed water may accumulate in the unit.
If the internal tank becomes full, the warning light will come on and the unit will stop operating until
the unit has been drained (evacuation #10). To drain the unit, refer to storage instructions p.2. If you
are using the unit on dehumidifying mode, make sure to install continuous drainage properly (refer
to continuous drainage p.17)
Timer (C)
Auto turn OFF : with the machine in running mode, press the timer button. Then set the desired wor-
king time in hours before shut down by pressing the "+" or "-" buttons.
Auto turn ON: With the machine in OFF mode, press the timer button. Then set the desired time de-
lay ON in hours by pressing the "+" or "-" buttons before the unit automatically starts running in the
latest used mode.
The time is adjustable between 1 to 24hours
Mode Control (D)
The mode control has three settings. A green light indicates which mode is currently being used.
• Cooling mode
heat exhaust hose (#13). Adjust fan speed and air temperature to suit your desired comfort level.
Use the buttons (-) and (+) to set the desired temperature between 16 and 32°C. After 10 seconds
the display will revert to room temperature.
Note: the air exchange hoses must vent outside the room when using cooling mode.
• Dehumidify mode
cooling mode. In this mode, If temperature is higher than 25°C, fan speed can be adjusted;
otherwise, fan speed is fixed to "low" .
In this mode, do not connect the exhaust hose and let the warm air return to the room. You will
need to install a drainage hose (evacuation #11), with the water discharging to the outside. (please
see the paragraph p.17)
• Fan Mode
: air is circulated throughout the room with no cooling.
Note: Unit doesn't need to be vented in fan mode. Adjust fan speed to suit your desired
comfort level.
Fan Speed Control (E)
The fan speed control has three settings: High, Medium and Low.
C
D
: During the cooling mode the air is cooled and hot air is expelled through the
: Air is dehumidified as it passes through the unit, without being in full
E