Congratulations on choosing to improve the
hygiene and image of your washroom! With
one simple hand motion, the enMotion
Recessed Automated Touchless Towel
Dispenser elevates the image of your facility,
helps improve hygiene, increases operational
efficiency, and helps you support the EPA's
guidelines to reduce waste.

TOOLS AND SUPPLIES

• Screwdriver
• Power Drill
• Pencil or Pen
• Level (recommended)
• 4 ea. #8 wood screws
STEP ONE
Unpack the dispenser and locate listed
components:
• 1 enMotion
®
Roll Towel Dispenser
• Dispenser Key
• 4 "D" Cell Batteries
• Instruction Guide
• Lifetime Guarantee Card
If anything is missing from the above list, call
1-866-HELLO GP (435-5647).
STEP TWO
Assembling enMotion
®
Dispenser
1. Locate key on right side of dispenser and open dispenser.
To request a twist knob for the dispenser instead of the key
provided, please call customer service at
1-866-HELLO GP (435-5647).
2. Load 4 "D" cell batteries in battery compartment
located in the rear of the dispenser.
= Battery
STEP THREE
Determining installation location
1. Determine mounting location for dispenser.
When placing dispenser, allow at least 4" on all sides from the
closest objects on the wall.
Note: Mounting should comply with ADA Guidelines.
Compliance is the responsibility of the installer.
2. Notice the metal static ground clip on the left side of the
backplate. This must be in contact with the wall to properly
ground the dispenser. Failure to properly ground the dispenser
will cause damage to the unit and may cause unit to become
inoperable.
3. If installing directly in a wall, a cut out of
15" high x 10.5" wide x 4" deep will be required.
Notice: The door comes mounted on the left side of the
housing. If there is not enough clearance for the door on the left,
refer to the directions below to switch the door from the left to
the right side.
ENGLISH
®
Directions to switch door opening:
1. Use a Phillips head screwdriver to remove the silver hinges on the left
side of the dispenser and save the screws. Once removed, the hinges
should separate from the black backplate.
2. Next use a flat-head screwdriver to remove the 2 crescent push
washers on the hinges so that the door can be lifted off of the hinges.
Save these washers.
3. Now use a Phillips head screwdriver to remove the lock assembly and
move it to the opposite side of the dispenser. Remove the silver cap
from the non-lock side and snap it into place on the opposite side.
4. Finally, reattach the hinges to the right side of the unit and hang the
door onto the hinges, adding the push washers from the previous step
to ensure that the door cannot be lifted off its hinges.
STEP FOUR
Adjusting Settings
1. The enMotion
®
dispenser's adjustable sheet length feature allows for
adjustments in towel length. The Length control switch is located
inside the cabinet just to the right of the sensor. Settings are:
• Left Setting - "Short" - maximum number of hand dries
• Middle Setting - optimal hand dry capacity
• Right Setting - "Long" - largest available towel
Note: Set Length to meet your needs.
2. The enMotion
dispenser's adjustable time delay allows towels to
®
dispense at different time intervals after a towel is removed from the
dispenser. Settings are:
• Left setting - Short
• Middle setting - Medium
• Right setting - Long
Note: The delay system is preset at the short option. To change the
delay find the control switch located inside the cabinet just to the
right of the sensor.
3. The enMotion
®
dispenser's adjustable sensor range feature allows for
adjustment in sensor range to provide dependable dispensing of your
towel. Settings are:
• Left setting - Short
• Middle setting - Medium
• Right setting - Long
Note: The sensor range is pre-set at the high option. To change the
sensor range, find the control switch located inside the cabinet just to
the right of the sensor.
4. The enMotion
®
dispenser's dispense mode system allows for
adjustment in how the towel is presented to the end user.
• "ODM" is On-Demand Mode (The towel will feed from the
cabinet after the user has activated the sensor.)
• "HM" is Hang Mode (The towel will always be showing. After
tearing off one towel, another towel will present itself.)
Note: The dispense mode system is preset on the On-Demand
Mode. To change the setting, locate the control switch inside the
cabinet just to the right of the sensor.
STEP FIVE
Testing the Dispenser
1. Load the dispenser with enMotion® Recessed Roll Towels according
to the instructions on the inside of the front cover.
2. Thread towel through rollers. Tuck edge of paper under the blue
transfer bar. Push blue auto-feed button located on the lower right
side of the cabinet.
3. Close dispenser cover. After short delay the dispenser is ready for use.
4. Dispense towels by moving hand in front of cabinet within sensor
range and tear off towel. Repeat this process 2-3 times to confirm
proper operation. If towel does not dispense while moving hand in
front of dispenser, open the dispenser and check the following:
ENGLISH