1 Safety Information

1.1 General safety information

 These
operating
instructions
information on using the vacuum pump. Please read
the operating instructions thoroughly and keep them
for later reference.
 The vacuum pump may only be commissioned after
the operating instructions have been read and fully
understood.
 In addition to these operating instructions, instructions
must also be provided in terms of the German "Health
and Safety at Work Act" [Arbeitsschutzgesetz] and the
German "Ordinance on Industrial Safety and Health"
[Arbeitsmittelbenutzungsverordnung].
 General safety regulations and European standards,
including those set by the machine manufacturers,
must be observed and adhered to.
 Please observe the accident prevention regulations for
condensers,
VBG
16,
especially
"Installation" and IV "Operation" and VBG 4 "Electrical
systems and equipment". The vacuum pump may only
be modified or changed with the approval of the
manufacturer.
 Installation and maintenance may only be carried out
by qualified specialist personnel.
 Sudden vacuum failure may lead to hazardous
situations.
 The vacuum pump may only be used for the purpose
for which it was intended.
 The vacuum pump may only be operated in a
flawless, fully-functional condition.

1.2 Intended use

 The vacuum pump is used for creating a vacuum.
 The vacuum pump is only suitable for evacuating dry,
non-aggressive and liquid-free gases.
 The figures apply to a height of 800 m above sea
level.
 The pump works entirely free of oil and therefore
should not draw in any oil mist.
 The ambient temperature may not exceed 45 °C.
 The Multi-Clamp vacuum pump should be stored in a
dry place and the development of condensation due to
water vapor should be avoided.

2 Startup

 Place the vacuum pump on an even and stable
support.
 Ensure that all the connections are free of oil, grease,
water or other soiling.
 There should be at least 10 cm of free space between
the device and adjacent walls, so that the air flow for
cooling is not restricted.
 You must ensure that the motor fan has free suction
and the cooling air can flow out unrestricted, so that
the inner temperature does not rise too greatly.
 Insert the power cable into a 230 V plug socket.
 The vacuum pump is now ready for use.

3 Description

3.1 Components

contain
important
section
IIIc
Item
Description
1
Carrying handle
2
Manometer
3
Filter cover
4
Vacuum connection
5
Housing cover
6
Filter
7
Outlet valve
8
Cable drum
9
ON/OFF power switch
10
Power cable with plug

3.2 Function and application

The suction pump is a dry-running rotary vane pump. It
is intended for creating the operating vacuum.
The Multi-Clamp vacuum pump must be positioned on a
stable, even surface.
Caution: Please ensure that the fan housing can be
freely vented.
If the vacuum pump is ready for operation, it can be
switched on via the power switch [9]. If the Multi-Clamp
vacuum pump is sucking against air at ambient
pressure, the manometer [2] shows a vacuum level of 0.
1
2
3
6
4
5
7
8
9
10
Page 1
Caution: If the filter [6] is very dirty, the maximum
possible end vacuum will not be reached.
Caution: During operation, the housing cover can heat
up to 100 °C. Long contact with skin may cause burns.
To release the workpiece, the power switch [9] must be
switched off and the system vented at ambient pressure.
The pump should be switched off before removing the
plug [10] of the device from the plug socket.
0 = OFF
Caution: Please note that the vacuum pump switches
off automatically if overloaded and switches back on
automatically once it has cooled down.
Caution: vacuum pump may not be switched on and off
more than 10 times per hour.