Maximum operating temperature
The high-power permanent magnets installed in the magnetic clamp will maintain their load-bearing capacity up to
a maximum operating temperature of 176°F (80°C). Exceeding this maximum operational temperature may cause
irreversible damage.
Detailed Performance Data for the MX-750-HL Hand Lifter
Values shown for load capacity of the MX-750-HL Hand Lifter are based on material A36 comparable to S235 for
the maximum, vertical tractive force with 0° deviation from the load axis and additionally under a 90° inclined load
in accordance with EN13155, in each case with a 3:1 safety factor. This manual does not contain any instructions
for use on round material. The MX-750-HL is designed for manual lifting of flat materials only. Round materials or
arched objects may not be lifted.
Note: The maximum total lifting weight by a single individual using the Hand Lifter should not exceed 70 lbs
including the Hand Lifter.
Table 2
Thickness of
material
Inches
0.08
0.12
0.16
>0.20
Thickness of
material
mm
2
3
4
>5
Load capacity in lbs
Clean, flat, ground
surface
Air gap <0.004 inches
0°
90°
66
22
110
55
110
66
110
75
Load capacity in kg
Clean, flat, ground
surface
Air gap <0.1 mm
0°
90°
30
10
50
25
50
30
50
35
Rusty, slightly
scratched surface
Air gap = 0.01 inches
0°
90°
55
17
88
26
110
44
110
55
Rusty, slightly
scratched surface
Air gap = 0.25 mm
0°
90°
25
8
40
12
50
20
50
25
Irregular, rusty or
rough surface
Air gap = 0.02 inches
0°
90°
48
15
75
22
100
33
110
33
Irregular, rusty or
rough surface
Air gap = 0.5 mm
0°
90°
22
7
35
10
48
15
50
15
8