Maintenance and Inspection of the Hand Lifter
The user is obliged to maintain and service the MX-750-HL Hand Lifter in compliance with the specifications in the
operating manual and according to the country-specific standards and regulations.
The below maintenance intervals are classified according to the recommended schedule.
Before every use...
visually inspect the entire Hand Lifter for damage
clean the magnetic contact area of any contamination (i.e. rust, metal chips) that would cause unevenness
of attachment or an air gap between the workpiece
Weekly...
make sure the activation lever is not bent or the plastic of the activation lever is not cracked
make sure the activation lever springs into the locking notch when in the ON position
inspect the magnetic contact area for any protruding scratches, pressure point deformations, and/or cracks
into the magnetic contact area. Have the Hand Lifter repaired by the manufacturer if any unevenness of the
magnetic contact areas is identified.
inspect the Handle for damage, deformation, cracks or wear and have it replaced if necessary
Monthly...
check the markings and labeling on the Hand Lifter for legibility, damage, modification, or removal. To meet
full compliance, the entire Hand Lifter must be returned to the manufacture for calibration and relabeling.
Annually...
have the load-bearing capacity of the magnet checked by the supplier or an authorized workshop, should
the application so require.
Unauthorized repairs or modification to the Hand Lifter are not permitted.
If you have any questions, please contact the manufacturer.
9