Heat-A-Ventlite
Combination
MODEL: 665RSP
Type IC suitable for use under thermal insulation
LOCATION
1. Mount heater to ceiling joists, or if necessary, to a header
installed between joists.
2. Caution: Do not mount heater closer than 12" to a
vertical surface. Do not mount over tub or in shower
enclosure.
3. Installation in existing construction requires an accessible
area above the desired location. Make sure that wiring
and ducting can be run to the location.
MOUNTING HEATER HOUSING
NEW CONSTRUCTION
Using Hanger Bars
Refer to Figure 1.
1. Insert hanger bars in slots provided in housing.
2. Locate heater housing between joists so that bottom of heater housing is even with the planned finished ceiling.
3. Use screws or nails (not provided) to secure hanger bars to ceiling joists.
Using Side Mounting Tabs
1. Locate heater housing next to ceiling joist.
2. Use wood screws (not provided) through keyhole slots in mounting tabs to loosely attach housing to ceiling joist.
3. Adjust housing so that it will be flush with the finished ceiling. When housing is properly adjusted, tighten screw in slots to
secure housing.
EXISTING CONSTRUCTION
1. Determine desired location for heater.
2. Drill a small hole through the ceiling at the desired location and stick a coat hanger or stiff wire through hole into attic to
help find the location from above.
3. Check the area above to make sure that wiring and ducting can be installed and that the installation will not interfere with
existing electrical wiring.
4. From above, place the housing between ceiling joists at the desired location. Using the housing as a template, mark the
area to be cut out along the bottom flange of the housing.
5. After making the cutout, install the housing in the opening using the hanger bars or mounting tabs as described above.
Make sure that the bottom of the housing is flush with the bottom of the finished ceiling.
®
INSTALLATION INSTRUCTIONS
READ & SAVE THESE INSTRUCTIONS!
FIGURE 1

Publicidad

loading

Resumen de contenidos para NuTone Heat-A-Ventlite 665RSP

  • Página 1 INSTALLATION INSTRUCTIONS READ & SAVE THESE INSTRUCTIONS! Heat-A-Ventlite ® Combination MODEL: 665RSP Type IC suitable for use under thermal insulation LOCATION 1. Mount heater to ceiling joists, or if necessary, to a header installed between joists. 2. Caution: Do not mount heater closer than 12" to a vertical surface.
  • Página 2 WIRING HEATER JUNCTION BOX All wiring must comply with local and national codes HEAT LIGHT VENT RECEPTACLE and unit must be properly grounded. RECEPTACLE RECEPTACLE (WHITE) WHITE 1. Run 120VAC, 60 Hz supply wiring to the wall switch. GREEN The unit must be wired on a separate 20 Amp circuit. WHITE 2.
  • Página 3: Instalación De La Caja Del Calentador

    INSTRUCCIONES DE INSTALACIÓN ¡LEA Y CONSERVE ESTAS INSTRUCCIONES! Combinación Heat-A-Ventlite ® MODELO: 665RSP Tipo IC, idóneo para ser usado bajo aislamientos térmicos UBICACIÓN 1. Instale el calentador en las viguetas del techo o, de ser necesario, en un cabezal colocado entre dos viguetas. 2.
  • Página 4: Instalación Del Reflectory La Rejilla

    CABLEADO CAJA DE UNIONES DEL CALENTADOR HEATER JUNCTION BOX Todo cableado debe cumplir con los códigos nacionales y RECEPTACULO RECEPTACULO HEAT DE LA DEL CALOR RECEPTACULO LIGHT VENT RECEPTACLE locales y la unidad debe ser puesta a tierra correctamente. VENTILACIÓN (BLANCO) DE LA LUZ RECEPTACLE...
  • Página 5 One Year Limited Warranty WARRANTY OWNER: NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one (1) year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
  • Página 6: Parts List

    Lens 53740-000 89765 Reflector 89765-000 35758 Lamp Socket 35758-000 85627 Wall Switch Assembly 85627-000 NuTone Attn: Parts Department NOTE: Always order by 4820 Red Bank Rd. Cincinnati, OH 45227-1599 current part number Phone: (513) 527-5426 Fax: (513) 527-5173 665RSP I.I.