Installation
MAX 10°
Install reflector maintaining it in axis with the beam.
For distance between 5 and 70 meters use only the reflecting panel you find
within the beam in order to have a reflecting surface of 20 x 20 cm.
For distance between 70 and 100 meters, add Kit BFS (3 reflecting panels)
to the panel given within the beam in order to obtain a reflecting panel of 40
x 40 cm.
In this case, panels must have all fixing holes in the same direction.
Install the beam maintaining it in axis with the reflector.
For installation onto the wall either reflector and
beam need flat cylindrical-head screws.
For correct working, either the beam and the reflector must
be on the same axis. Max tolerance is about 10° in both
vertical and horizontal position.
Exceeding this, the beam will not work properly.
MIN 5 MT
MAX 100 MT
Pointing holes
Fixing holes
Insert small mirror BF TEST (this
accessory is necessary for a
correct adjusting) in right position as
shown on side picture, maintaining the
pointing hole upwards.