TESTING THE GAS SUPPLY PIPING SYSTEM
When test pressures exceed 0.5 PSI (3.5 kPa), the fryer and its individual shutoff valve must be disconnected
from the gas supply piping system.
When test pressures are 0.5 PSI (3.5 kPa) or less, the fryer must be isolated from the gas supply piping
system by closing its individual shutoff valve.
LEVELING THE FRYER
Check the level of the fryer front-to-back and side-to-side after gas connections have been made by placing
a bubble level on top of the fryer. Adjust the leveling legs as needed to level the fryer.
After moving into the final position, check again that the unit is level using a bubble level.
10