Permanent Light Function
If a mains switch is installed in the mains supply lead,
the light is capable of the following functions in add-
ition to the simple ON/OFF function:
Sensor operation
1) Switch light ON (when floodlight is OFF):
Switch OFF and ON once.
LEDs stay ON for the period selected.
2) Switch light OFF (when floodlight is ON):
Switch OFF and ON once.
Floodlight goes out or switches to sensor mode.
Operation and Maintenance
The unit is not suitable for special burglary alarm
systems since it lacks the tampering protection pre-
scribed for this purpose. Weather can affect opera-
tion of the sensor-switched LED floodlight. Strong
gusts of wind, snow, rain and hail may cause the light
Technical Specifications
Sensor-switched LED floodlight
XLed 10
Power supply:
230-240 V/50 Hz
Output:
10 LEDs, approx. 30 W
Light colour:
approx. 4100 kelvin (warm white)
Luminous flux:
2000 lumens
Efficiency:
66.66 lm/W
Additional switching capacity:
Life of LEDs:
Angle of coverage:
240° with sneak-by guard
Detection reach:
12 m all round
Projected area:
250 cm
2
+ 103.36 cm
Swivelling range of
sensor unit:
± 80°
Swivelling range of housing:
200° vertically
270° horizontally
Time setting:
5 sec. – 15 min.
Twilight setting:
2 – 2000 lux
Basic light level:
10% all night / 10 min. / OFF
Permanent light ON:
4 hrs., selectable
Dimensions (h x w x d):
205 x 200 x 200 mm
Weight:
2200 g
Temperature range:
-20 °C to +50 °C
IP rating:
IP 44
Protection class:
I
Manual override
1) Activate manual override:
Turn switch OFF and ON twice. The floodlight is set
to stay ON for 4 hours (red LED lights up behind the
lens). Then it returns automatically to sensor mode
(red LED OFF).
2) Deactivate manual override:
Switch OFF and ON once. Floodlight goes out or
switches to sensor mode.
Important:
The switch should be actuated in rapid succession
(in the 0.5 – 1 sec. range).
to come ON when it is not wanted because the sensor
is unable to distinguish sudden changes in tempera-
ture from sources of heat.
The detector lens may be cleaned with a damp cloth
if it gets dirty (do not use cleaning agents).
XLed 25
230-240 V/50 Hz
25 LEDs, approx. 62 W
approx. 4100 kelvin (warm white)
4000 lumens
64.52 lm/W
Filament bulbs, 800 W max. at 230 V AC
Fluorescent tube, 400 W max. at cos ϕ = 0.5,
inductive load at 230 V AC
Fluorescent lamps, low-energy lamps,
LED lights with electronic ballast at 230 V AC,
4 x 60 W each max., C ≤ 88 μF
up to 50,000 hrs. (for 3 hrs./day approx. 45 years)
240° with sneak-by guard
12 m all round
2
420 cm
2
+ 103.36 cm
± 80°
200° vertically
270° horizontally
5 sec. – 15 min.
2 – 2000 lux
10% all night / 10 min. / OFF
4 hrs., selectable
300 x 200 x 200 mm
2960 g
-20 °C to +50 °C
IP 44
I
- 12 -

Troubleshooting

Malfunction
Sensor-switched LED floodlight
without power
Sensor-switched LED floodlight
will not switch ON
Sensor-switched LED floodlight
will not switch OFF
Sensor-switched LED floodlight
keeps switching ON and OFF
Sensor-switched LED floodlight
switches ON when it should not
Declaration of Conformity
This product complies with
- Low Voltage Directive 2006/95/EC
- EMC Directive 2004/108/EC
- RoHS Directive 2011/65/EC
- WEEE Directive 2012/19/EC
2
Functional Warranty
This STEINEL product has been manufactured with
utmost care, tested for proper operation and safety
and then subjected to random sample inspection.
STEINEL guarantees that it is in perfect condition
and proper working order.
The warranty period is 36 months and starts on the
date of sale to the consumer. We will remedy defects
caused by material flaws or manufacturing faults.
The warranty will be met by repair or replacement of
defective parts at our own discretion. The warranty
shall not cover damage to wear parts, damage or
defects caused by improper treatment or mainten-
ance. Further consequential damage to other objects
is excluded.
Cause
Remedy
■ Fuse faulty, not switched ON,
■ Fit new fuse; switch ON
break in wiring
mains switch; check wiring
with voltage tester
■ Short circuit
■ Check connections
■ Twilight control set to night-time
■ Adjust setting
mode during daytime operation
■ Mains power switch OFF
■ Switch ON
■ Fuse faulty
■ Fit new fuse, check connection
if necessary
■ Detection zone not properly
■ Re-adjust
targeted
■ Continuous movement in the
■ Check zone and readjust if
detection zone
necessary or apply shroud
■ Animals moving in the
■ Tilt sensor higher or apply
detection zone
specific shrouds; adjust zone,
or apply shrouds
■ Wind is moving trees and
■ Change detection zone
bushes in the detection zone
■ Cars in the street are being
■ Change detection zone
detected
■ Sudden temperature changes
■ Adjust detection zone or install
due to weather (wind, rain,
in a different place
snow) or air expelled from fans,
open windows
■ Sensor-switched LED floodlight
■ Mount sensor-switched LED
is moving (swaying) due to gusts
floodlight on a firm surface
of wind or heavy rain.
Claims under the warranty will only be accepted if the
unit is sent fully assembled and well-packed with a
brief description of the fault, a receipt or invoice (date
of purchase and dealer's stamp) to the appropriate
Service Centre.
Repair service:
Please ask your nearest service
centre how to proceed for repairing
faults not covered by the warranty or
occurring after the warranty expires.