Abicor Binzel DAV Guia De Instalacion página 34

Estación de corte de hilo
Ocultar thumbs Ver también para DAV:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

11 Dismounting
Fault
Cause
No signal with the
• Proximity switch loose or faulty
final position scan
• Cable loose or faulty
option:
Tab. 9
Troubleshooting
11 Dismounting
12 Disposal
12.1 Materials
EN - 16
Dismounting may only be carried out by specialized personnel. Please make
sure that the shutdown procedures are strictly observed before the dismounting
work begins. Ensure this also for the components integrated into the welding
system.
DANGER
Risk of injury due to unexpected start-up.
For the entire duration of maintenance, servicing, dismounting and repair
work, the following instructions must be adhered to:
• Switch off the power supply.
• Close off the compressed air supply.
• Switch off the entire welding system.
• Pull the mains plug.
NOTE
• Observe the information given in section 8 Putting out of operation on
page EN-13.
1 Unscrew four screws and take off the wire cutting device DAV.
For disposal, the local regulations, laws, provisions, standards and guidelines
must be observed. For the product to be properly disposed of, it first must be
dismounted.
 See 11 Dismounting on page EN-16
This product is mainly made of metallic materials which can be molten in steel
and iron works and are thus almost infinitely recyclable. The plastic materials
used are marked in preparation for sorting and separation of the materials for
later recycling.
Solution
• Reposition and clamp in place
• Replace
DAV

Publicidad

Tabla de contenido
loading

Tabla de contenido