THE AIR CONDITIONER WILL NOT OPERATE
Check if...
Then...
Wallplugdisconnected.
Housefuse blownor cimuitbreakertripped.
PowerisOFF.
Unitwasturnedoffandthenon tooquickly.
TEMPControl s et warmer thanroomtemperature.
Pushplugfirmlyintowalloutlet.
Replace fusewithtimedelaytypeor resetcircuitbreaker
Pushthe powerbutton.
Turnunitoff andwait3 minutes beforerestarting.
TurnTEMPControl t o a lowertemperature.
AIR FROM UNIT DOES NOT FEEL COLD ENOUGH.
Check if...
Then...
FANSPEEDsetat LOW.
TEMPControlsettoo warm.
Roomtemperature below66°F(19°0).
Temperature sensingtubetouching evaporator c oil,
located behindair filter.
PushFANSPEEDbuttonto setat HI.
TurnTEMPControl t o alowertemperature.
Coolingmaynot occuruntilroomtemperature rises above66_F(19°C)
Straighten tubeawayfromevaporator c oil.
"n, lEAIR CONDmONER
COOtJNG, BUT ROOM ISTOO WARM -ICEFORMING ONCOOLING COIL BEHIND FRONT G RILLE.
Check if...
Outdoortemperaturebelow66°F (19°C).
Air filter may be dirty.
TEMPControlsettoe coldfornight-time cooling.
Then.,.
To defrostthe coil,set MODEto FAN
Clean air filter. Referto Maintenance sectionof owner'smanual.
To defrost t he coil,set the MODEto FANor"High Cool"withthe
TEMPcontrol to a highertemperature
"I]'IE A IRCONDI]10NER
COOUNG, BUT ROOM ISTO0WARM
Check if...
Dirtyair filter- air restricted.
TEMPControlsettoowarm.
Front o f unitis blockedby drapes, b linds,furniture,
etc.Air distribution i s restricted.
Doors,windows, r egisters, e tc.open.Coldairescapes.
Unitrecently tumedon inhot room.
Cleanair filter.Refer t o Maintenance s ectionof owner'smanua{.
TurnTEMPcontrol t oa lowertemperature.
Clearblockage infrontof unit.
Closedoors,windows, r egisters, e tc.
Allow additional timetoremove s tored heat f rom walls, ceiling, _or, andfurniture.
THE AIR CONDITIONER TURNS ON AND OFF RAPIDLY.
Check if...
Then...
I Outsidetemperatureisextremelybet.
I SetFANSPEEDonHItobnngairpastcoolingcoiltaster.
NOISE WHEN UNIT IS COOLING.
Check it'...
Then...
I Sound offanhitting
water - from the moisture removal
system This isnormal when humidity
ishigh. Close doors, windows,
and registers
Windew vibratlen
- poor installatlen.
I Refer t oinstallation instn,lctlens
orcheck with installer.
WATER DRIPPING INSIDE ROOM WHEN UNIT IS COOLING.
Check if...
Then...
I Theairsendlti°ner isimproperly lestalled"
! ]3ltairc°nditlener
slightly t ° the°°tsidet°all°wwater d rainage" Refer
toinstallation
instructions cf check with installer.
WATER DRIPPING OUTSIDE WHEN UNIT IS COOLING.
Check if...
Then...
I ]]le unit i sremoving large quantities
ofmoisture
"this isnormal dudng exceasively humid days.
from humid room.
I
]