Positioning - gas fired boiler and
DHW cylinder
Gas fired boiler and
DHW cylinder pipework
Three-way diverter valve installation
Bend -
heating
flow
Cap - heating return
Three-way
diverter valve
Connection set
for installation on finished walls
Install the gas fired boiler in accordance with installation instructions.
Locate the DHW cylinder below and in alignment with the boiler.
Three-way
diverter valve
Gas fired boiler
Heating flow
DHW flow
DHW
DHW cylinder
Gas fired boiler and DHW cylinder are installed as shown in the following steps:
- Remove the cap from the heating return.
- Remove the bend from the heating flow.
- Install the three-way diverter valve from the connection set with the enclosed gaskets
to the heating flow.
Connection
panel
DHW cylinder cut-out
for supply lines
Gas
supply pipe
Air vent valve-
cylinder return
(at the pump)
Air vent valve -
DHW flow
Safety valve drain
Heating return
DHW return
Cold water