Idiomas disponibles

Reading resolution
Output current
Max. open circuit voltage
Immunity to spurious voltage
interference
Earth resistance of auxiliary
rods
Battery status checking
Advanced Features
Soil Resistivity Computing
Data Output
Built-in printer
Power supply
Safety Class
E.M.C.
Electrostatic immunity
Electromagnetic irradiation
immunity
Environmental Protection
0.01 Ω in the resistance measurement.
:
0.01 Ωm in the resistivity measurement.
0.1 V in the voltage measurement.
The short-circuit current is limited to less than
:
20.0 mA rms
:
50 V
During the R measurement, it allows for the
:
presence of spurious voltage up to 7 V~ , with a
error < 10%.
In the R measurement it allows Raux up to 50 kΩ
:
with error < 30%
The battery charge status is verified under
:
normal using conditions.
Automated detection of abnormal conditions that
:
may cause excessive errors (low battery, too
high noise interference, too high test spikes
resistance)
When performing soil resistivity measurements,
:
the operator informs to the EM-4058 the distance
between spikes and the equipment automatically
computes soil resistivity using the Wenner full
equation.
:
USB
For a printed register document of measured
:
values.
By means of an internal rechargeable battery,
:
LFP 12 V 3 Ah.
In accordance with IEC 61010-1
:
In accordance with IEC 61326-1
:
:
In accordance with IEC 61000-4-2
:
In accordance with IEC 61000-4-3
:
IP-54 with closed lid.