18
RBMP1 Connections <--> PSR2 (PSE/PSU/PSC3000) and PSF2 (PSC7000/1)
Two-way CONNECTION : The RBMP1 can be placed at
any point along the route of the cables
RBMP1
from the fi rst to thefi nal
PSR2 or PSCA2. The
PSR2
distance (meaning the route
of the connection cable)
must not be longer than
1000 m
PSCA2
PSCA2
Cable*
NOT INCLUDED
recommended cable:
unshielded twisted
multi-pair
(CAT 5 - U/UTP - AWG24)
Each unit is identifi ed by the RBMP1 through sequential progressive numbering, and does not
depend on the position of the unit along the route of the connection cable; this number (also
called 'address') must be entered on the relative DIP switch on the control board of the peripheral
PSR2/PSF2
* the PSR2 control boards equip the PSE/PSU/PSC4000 units, while the PSF2 equip
* AWG24 connection cable colours
√ White/Orange twisted pair on GND
√ White/Green twisted pair to be split:
• White on A
• Green on B
Insulate the remaining two pairs.
PS BARCODE -
PSR2
(Entrance or exit unit and automated pay station)
(
ENTRANCE AND EXIT CAN BE CONNECTED TO EITHER
the PSC6000/1 pay stations.
Hardware and connections
RBMP1
to the next* PSR2/PSF2
1
2)
TERMINAL
OR
(
ENTRANCE AND EXIT CAN BE CONNECTED TO EITHER TERMINAL
Cable*
NOT INCLUDED
recommended cable:
unshielded twisted
multi-pair
(CAT 5 - U/UTP - AWG24)
PSR2/PSF2
to the next* PSR2/PSF2
1
2)
OR