PSM3000 connections (RBMP1) <--> Digital inputs
Digital inputs are used to connect the magnetic coils which provide a real time count of the number of vehicles in the car park. They
control the traffi c lights independently from the PSE/PSU3000 entrance and exit units. They are often used in multi-level parking, with
one entrance and one exit. The coils may be used to count the exact number of vehicles on each level, so that the exact number of
free spaces is known for each parking level.
PSU3000
PSC3000
PSE3000
RBMP1
PS BARCODE -
Example of a multi-storey car park with vehicle counting coils for each level.
Exit
magnetic
coil
PSM3000
Traffi c light
Entrance
magnetic
coil
Hardware and connections
Traffi c light
Method for connecting additional coils to RBMP1/PSIO, for a precise count
of the number of vehicles on each level. It is preferable to use a 2 channel
detection device, such as the SMA2, in unidirectional mode. Also see
product documentation.