Commissioning
Caution
During operation high dynamic forces arise which can
damage the mechanical components.
Make sure that the cylinder is retracted when the
mounting cycle is started or continued (see table
Mounting cycle").
Make sure that movement to the waiting position is
only undertaken from the end position reached against
the pressure−neutral rotary drive.
S Pressurize the rotary drive via the 5/3−way valve in
both chambers before the cylinder is retracted.
S Reset the 5/3−way valve to the basic position as soon
as the HSW−... reaches the end position again
(starting position).
Pressurize your system slowly.
S
Observe the commissioning instructions in the
S
operating instructions for the HSW−...
Carry out a test run as described in the operating
S
instructions for the HSW−...
18
Festo BW−HSW−... 0510NH English