Electrical cut-off device: It allows immediate cut-off of all the functions of the machine in
the event of an anomaly. Intervention of this guard includes emergency stoppage of the
machine. The device that caused stoppage (fuse) must be restored before re-start by
positioning, before resetting, the start button in the stop position.
1.7. Risks deriving from machine use
1.7.1. Risk of noise
The sound level was detected measuring emission with the machine in motion in
compliance with standard UNI EN ISO 11201: 2010. The following values were
obtained:
- Average acoustic pressure LpA (A) dB 79,72
From the values found, it was concluded that machine
operation causes a high level of noise.
During use of the machine, it is therefore compulsory for operators to use ear
protection such as earmuffs or ear plugs, to avoid damaging ears over time.
1.7.2. Risk of vibrations
The level of vibrations was measured with the machine in motion in compliance with the
standard ISO 5349-2: 2015 to assess vibrations transmitted to the HAND-ARM system.
The following value was obtained:
Hand-arm vibration level: 9.39 m/s
You are advised to assess use of possible PPE according to local legislation.
20
considering heavier use of the opened machines 3 m.
2
Castellari S.r.l.
•
Via Lasie 16/E
VERTIGO 12V
•
IMOLA (BO)
5