Understanding Error LEDs.
Error Conditions will be indicated by the following LEDs.
LED
Reason/Solution
Solid
Charger is in Standby mode or Battery voltage is too low for charger to detect.
Solid
Battery voltage is too high for the selected charge mode. Check the battery and charge mode.
Solid
Possible battery short / Battery will not hold a charge. Have battery checked by a professional.
Solid
Reverse polarity. Reverse the battery connections.
Solid
Charger internal temperature too high / Charger will resume function once the Charger internal temperature drops.
Flashing
Charger ambient temperature too cold / Charger will resume function once the Charger ambient temperature rises.
Charging Times.
Charging Times.
The estimated time to charge a battery is shown below. The size
of the battery (Ah) and its depth of discharge (DOD) greatly affect
its charging time. The charge time is based on an average depth of
discharge to a fully charged battery and is for reference purposes
only. Actual data may differ due to battery conditions. The time
to charge a normally discharged battery is based on a 50% DOD.
Temperature will also impact charging times. The GENIUSPRO25
Series features thermal compensation that automatically adjusts
charging profiles to maximize charging performance.
Battery Size
Approximate Time to Charge In Hours
Ah (Amp hour)
6V
25
0.75
50
1.5
100
3
200
6
500
15
1000
30
12V
24V
0.75
1.5
1.5
3
3
6
6
12
15
30
30
-