motion and up to 5 meters radius for walk
across motion at the mounting height of
2.5 meters. (FIGURE 3)
FIGURE 3
INSTALLATION
Switch off the power source or wall switch
(1)
before installing.
In order to install the sensor, drill a round
(2)
hole of about 70mm in diameter on the
drop ceiling.
upward so they can fit into the hole.
(FIGURE 4)
FIGURE 4
Gently put the unit into the hole.
(3)
Release the spring clips and the clips will
fasten the unit firmly onto the drop ceiling.
(FIGURE 5)
FIGURE 5
Caution: When new setting is required or for
other reason to take out the sensor, please
move the drop ceiling to a position where you
Turn both spring clips
can take out the unit more easily.
carefully pull down the unit (use a flathead
screwdriver if necessary, but be careful not to
damage the sensor).
watch out for the fingers not being flicked by
the spring clips. (FIGURE 6a & 6b)
WIRING INSTRUCTION
Switch off the power source or wall
(1)
switch.
Lift the protection case to remove it from
(2)
the main body.
screws to release the cable fastener.
(FIGURE 7)
Cable
fastener
On the rear of the main body you can find
(3)
the wiring terminals. (FIGURE 8)
12
During the process,
FIGURE 6a
Watch out
for the clips
FIGURE 6b
Then unscrew two
Protection
case
FIGURE 7
Then