FIGURE 8
Study FIGURE 9a for wiring information.
(4)
Then thread and fasten the power cable
as indicated in FIGURE 9b.
Warning: Incorrect wiring could damage
the sensor or connected load, and also
may cause electrical harm.
FIGURE 9a
The unit can support slave detector (sold
(5)
separately) connection for large area
coverage such as in a corridor or passage
(FIGURE 10a).
will turn on when either the master or
slave detector detects motion.
case of slave detector connection, study
FIGURE 10b for wiring information.
FIGURE 9b
The connected lamps
In the
Door
Slave
detector
Master
detector
Door
FIGURE 10a
TEST / ADJUST THE SENSOR AND
LIGHTING SYSTEM
(1) TEST THE SENSOR
 Turn the LUX control counterclockwise to
the "T" (TEST) position, and then also turn
the TIME control counterclockwise to the
edge position. (FIGURE 11)
 Turn the wall switch on and the sensor will
take about 60 seconds to warm up. After
warming-up, the light will turn off.
 Walk through the coverage area and the
light will turn on. This confirms that the
wiring was done properly and that the light
is working.
about 5 seconds and then turn off. Wait
until the light turns off and then move
again to test the sensor.
(2) SETTINGS
 TIME ADJUSTMENT
The TIME control knob determines how
long the light will stay on after motion is
detected.
13
FIGURE 10b
FIGURE 11
The light will turn on for