Installation Instructions - Cadet BTF1 Instrucciones De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

1. All electrical work and materials must comply
with the National Electric Code (NEC), the Occu-
pational Safety and Health Act (OSHA), and all
state and local codes.
2. Use copper conductors only.
STEP 1
Turn the electrical power off at
the circuit breaker or fuse box.
STEP 5
Refer to the instructions in Part 2 that correspond to your thermostat application.
BTF1
240/208
Volt
Application
GROUND
SCREW
A.
Connect a hot supply wire to the red
thermostat wire.
BTF1
120 Volt
Application
GROUND
SCREW
A.
Connect the hot supply wire to the
red thermostat wire.
BTF2
240/208
Volt
Application
GROUND
SCREW
A.
Connect the black thermostat wires
to the loose heater wires.
Page 2

INSTALLATION INSTRUCTIONS

Wiring Instructions - Part 1
STEP 2
Remove the junction box cover
at the end of the baseboard you
wish to wire.
Wiring Instructions - Part 2
GROUND
SCREW
B.
Connect the black thermostat wire to
one of the heater wires.
GROUND
SCREW
B.
one of the heater wires.
GROUND
SCREW
B.
red thermostat wires.
Proceed to Part 3.
3. Turn off power to heater circuit at main discon-
nect panel.
4. Connect grounding lead to grounding screw
provided.
GROUND
SUPPLY
GROUND
SCREW
STEP 3
Connect the supply grounding
wire to the green grounding
screw provided.
Connect the black thermostat wire to
Connect the hot supply wires to the
GROUND
SCREW
STEP 4
Disconnect one factory connector
on the side you have open,
leaving two loose heater wires.
IMPORTANT: If wiring on the
left side, disconnect ONLY
ONE factory connector!
GROUND
SCREW
C.
Connect the remaining hot supply
wire to the remaining heater wire.
Proceed to Part 3.
GROUND
SCREW
C.
Connect the neutral supply wire to
the remaining heater wire.
Proceed to Part 3.

Publicidad

Tabla de contenido
loading

Tabla de contenido