STEP THREE
Side View – Cover Open
Determining the
Installation Location
1. When placing
dispenser, allow at
least 4" on all sides
from the closest
objects on the wall.
Note: Mounting
should comply with
ADA Guidelines.
Compliance is the
responsibility of
the installer.
Front View
14.50"
15.60"
STEP FOUR-A
Mounting the Dispenser Without Mounting Brackets
1. Mark and drill screw holes. Install wall anchors.
2. Align dispenser with screw holes. Check level of
dispenser.
3. Use four screws to secure dispenser to the wall.
Rear View
4.00"
8.00"
5.25"
42"- 44"
9.00
9.00
From Floor
Recommended
STEP FOUR-B
Mounting the Dispenser With Mounting
Brackets
1. Fit two 54019 mounting brackets together. (Brackets sold
separately.)
2. Mark and drill screw holes. Install wall anchors.
3. Align combined bracket with screw holes.
ENGLISH
19.75"
19.25"
Side View
9.50"
Dispenser
Release Tab
5.00"
7.40"
4. Use four screws to secure combined bracket to the wall.
5. Fit dispenser on bracket. Lock into place by gently pulling
downward. Listen for a click indicating dispenser is
properly secured.
6. To remove dispenser, locate flexible tabs on center of
brackets. Push tabs inward and gently pull dispenser
upward.
STEP FIVE
Adjusting the Settings
The Cormatic
dispenser's
®
adjustable settings are
located inside the dispenser
on the lower right side.
1. The "Adjustable Sheet
Length" (ASL) system
allows for adjustments in
towel sheet length.The
sheet lengths are:
• "S" Short towel (maximum number of hand dries)
• "M" Medium towel (optimal hand dry capacity)
• "L" Long towel (largest available towel)
Note: The ASL system is pre-set at the "L" option.
Set ASL to meet your needs.
2. The "Adjustable Time Delay" (ATD) system allows
towels to dispense at different time delay intervals
after a towel is removed from the dispenser. Settings are:
• "S" Short Delay
• "M" Medium Delay
• "L" Long Delay
Note: The ATD system is pre-set at the "M" option.
Set ATD to meet your needs.
3.The "Adjustable Sensor Range" (ASR) system allows
for adjustment in sensor range to provide dependable
dispensing. Settings are:
• "S" Short Range
• "M" Medium Range
• "L" Long Range
Note: The ASR system is pre-set at the "M" option.
Set ASR to meet your needs.
4. The "Dispense Mode" (DM) system allows for
adjustment in how the towel is presented to the end user.
Settings are:
• "On Demand" (The towel will feed from the dispenser
after the end user has activated the sensor.)
• "Hanging Towel" (The towel will always be showing.
After tearing off a towel, another towel will present
itself.)
Note: The DM system is pre-set at the "On Demand"
option. Set DM to meet your needs.
STEP SIX
Operating the Dispenser
1. Load Cormatic
®
or Ultima
®
Towels (SKU# 2910P, 2930P,
29500 or 2530).
Note: Refer to the illustrated instructions in the next
section.
2. Dispensing Cormatic
®
or Ultima
A. Wave hand approximately 2"- 2.5" across front of
dispenser. A Cormatic
®
or Ultima
automatically dispensed.
ENGLISH
®
Towels
®
towel is