CYCLE PARAMETERS FOR Bi-PULSED MIG WELDING MODE IN CONTINUOUS CYCLE
Parameter
Drop release force correction.
D
Arc length correction in upper working point of dual pulsed-
CBP
arc.
MOD
Pulse mode (2T, 4T and 4T special)
TPR
Gas pre-flow time.
IS
Initial current (just in 4TS mode)
Current ramp-down time in arc-start and arc-end. (just in
DWS
4TS mode)
IE
End crater current (just in 4TS mode)
TPS
Gas post-flow time.
FDC
Approach speed.
TBB
After-burning time correction.
FBP
Dual pulsed-arc frequency
± speed differential for obtaining both working points of the
DBP
dual pulsed-arc.
DCL
Time of dual pulsed-arc high speed.
DIM
Dimensional system (Ø/vh).
REF
Cooling mode
tacer
The time in approach process (Limited).
tci
Time of interrupted cycle (Limited)
Troff2
Cooling disconnection time (AUT Mode)
4TS pulse mode and Bi-Pulsed mode signalling :
The "Special" 4TS mode will be indicated with the symbol ↑↓ situated further to the right, and which will be
flashing.
The Bi-Pulse mode (FBP≠ OFF) will be showed with the indication "PULSE " flashing.
GALA INVERMIG SYNER 230 MP Bi-PULSE
PARAMETER DESCRIPTION
CONFIGURABLE
FACTORY VALUE
VALUE
-10 ÷ 10
(20 positions)
-30%÷ 30%
U
upper
2
2T ; 4T ; 4TS
0÷3.0 sec.
50÷400% vh
0÷10.0 sec.
10÷200% vh
0÷5.0 sec.
10 ÷100% Vh
-20 ÷ 20 (ms)
0.00 (150 – 4*Vh)
0.5÷5.0 Hz
10÷80 %
20÷ 80% (1/FBP)
MM ; IN
AUT/ON/OFF
Not adjustable
value
Not adjustable
value
Not adjustable
value
58
0
0 %
2T
0.3 (sec.)
200 % vh
0,6 (sec.)
50% vh
0,5 (sec.)
33 (% vh)
3.3
35%
50%
MM
OFF
5 s max.
4 s max.
120 sec.