Parameters
C1. Fahrenheit or Celsius Degrees.
-
The LCD displays the temperature unit selected: ºC or ºF.
C2. Control Adjustment.
-
The kind of temperature control can be modified with this parameter:
PID
Hysteresis 0,25ºC.
Hysteresis 0,35ºC.
Hysteresis 0,50ºC.
Hysteresis 0,75ºC.
C3. Correction of ambient temperature measures.
-
If there is a difference between an external thermometer and the temperature displayed by the unit, with C3
parameter it is possible to influence on the sensor in order to balance the difference. (-3ºC to +3ºC in 0,1 steps).
C4. Firmware version.
-
Information about the current firmware version of the unit.
C5. Open Window Activation
-
ON/OFF. With the parameter in ON, the open window detection is activated.

Unit reset

The unit reset remove the adjustment realized in the unit, and establishes de default values. It removes the programming and
disassociate the device from the RF network if the unit was associated with a G-Control Hub. To reset the unit, hold OK/Mode
and Config/Prog keys simultaneously for 10 seconds, the next figure will be displayed.
To confirm the reset of the unit press OK/Mode key, to cancel it any other key can be pressed.

Default Values

Operation mode
Comfort temperature
Economic temperature
Frost protection temperature
Ambient sensor Offset
RF associated
Temperature Unit
Open Window Detection
Control mode
Default Programming in AUTO Mode
OFF
19ºC
17ºC
5ºC
0ºC
No
ºC
Disabled
PID
Economic 24h*7
17
EN