ADAPTIVE START CONTROL
RFE Plus electronic control analyses the heating requirements of the room where the radiator is installed using this information
to turn on the heating element in advance in order to reach the set point temperature at the desired time.
When Adaptive Start Control is working, the word AdAP will be displayed alternating with the status of the current mode.
Note: To activate the adaptive start control please refer to ADVANCED FUNCTION ACTIVATION section.
ADVANCED FUNCTION ACTIVATION
Advanced functions Open Windows Detection and Adaptive Start Control are disabled by default. To enable / disable these
functions, the following steps must be followed:
Move the selector to
maintaining the
key at least five seconds.
The display will show
disable Open Windows Detection function.
Confirm the new value for the function by pressing the PRG key. The next function (AdAP) is shown alternating with its status
(On or OFF). Use the navigation keys
function by pressing the PRG key.
5.- UNIT RESET
The heater reset establishes the factory configuration of the heater removing the programming, establishing the daily
programming and disabling the advanced functions. To reset the unit, hold the PRG key for 4 seconds, the display will show
InIC
to indicate the heater has been reset.
6.- CLEANING AND MAINTENANCE
The radiators do not precise any special maintenance providing thermal comfort during large periods. Clean dust with a dry,
soft cloth only when the unit is disconnected and cold.
Do not use solvents or abrasive products for cleaning.
This thermal radiator has been manufactured under an assured quality system using environment friendly processes.
Please take the heaters to a clean point once their useful life is finished, in order to recycle their materials in the right way.
7.- TROUBLESHOOTING
The thermal radiator does not heat.
The room does not reach the required
temperature.
DAY and NIGHT luminous indicators are
lit at the same time
The display shows "Err1" or "Err2"
Only daily programmes
The keyboard does not respond.
0
position, the display will be Off. Press the
OPEn
alternating with the status of the function (On or OFF). Use the navigation keys
+
–
or
to enable / disable Adaptive Start Control function. Confirm the new value for the
Check the heater or the air inlets are not covered.
If the display shows the time, press the
Check that the DAY or NIGHT temperatures are right.
Check the selected temperature is in accordance with the desired
temperature. Maybe the room needs more heating power.
Continuous mode has been selected.
If the knob is in the "I" Position, turn it to the "P" position to return to the
program mode if required.
If the knob is in the "P" Position, hold the Sun key for 4 seconds to return to
the programming.
Contact the after sales service.
The controller is in single 24hr mode (factory default). See WEEKLY
PROGRAMMES section to switch to 24hr/7days mode.
If the display shows
the
key and at the same time turn the selector to
, the keyboard is locked. To unlock it, press
key more than six seconds.
16
+
key to switch on the heater.
P
position
–
or
to enable /