Lisbona 2
English
Condensate
• poor room conditi ons
• poor air venti lati on
• the window heaters do not work • check electrical connecti ons.
• the windows are not closed
properly
Cabinet
• poor room conditi ons
temperature
is too high or
• output air temperature is out-
too low
side the specifi ed range
• the cabinet is defrosti ng.
• the capacitor or the evaporator
are freezing.
• the capacitor or the evaporator
are obstructed or dirty.
• the load is not distributed even-
ly
Water leaks,
• cabinet drains are obstructed or
bad smell
damaged
• water collecti on tray is sealed
incorrectly
• water collecti on tray overfl ows • check wiring of evaporati on heater
• lacking coupling between cabi-
nets in channel or sealed incor-
rectly
Frost or ice
in the cabinet
• fans do not work
in the evaporator
• heaters broken
• Sdef probe detached
• air currents that alter the circu-
lati on of refrigerated air
i
in all cases not described or where it is not possible to solve the problem by following these
directi ons call the nearest authorised aft er-sales centre.
26. Assembly/disassembly instructi ons
DANGER! Live parts. Electrocuti on.
REMOVE THE ELECTRIC POWER SUPPLY BEFORE ANY OPERATION!
Follow chapters 1-2-3-4-5
Protect the hands with work gloves.
52
• check the positi on of the cabinet inside the
store chap.12
• check the operati on of fans and wiring
• check heaters operati on.
• close the windows properly
• check the positi on of the cabinet inside the
store chap.12
• check the operati on of evaporator fan
• check wiring and input voltage
• the fans are installed reversely; check and re-
store the air fl ow directi on
• check that fan plenum is suffi cient and not
obstructed
• check the intake pressure that should comply
with rated specifi cati ons
• check defrosti ng parameters
• check that the sucti on line is not obstructed
• proceed with cleaning
• load the goods in order (Fig.14)
• release the drains,
• repair or replace the drains
• seal it properly
• check the operati on of evaporati on heater
• install and seal the joints
• check electrical connecti ons.
• check the venti lati on inside the store
05060167 00 09-08-2016