Note: If having the 0-10 V Gateway; the algorithm will, in addition, consider the minimum and maximum voltage values established
by the installer within the menu
Lite settings. You can use this parameter to define base set-point temperature for zones with Airzone Lite. Besides, you can
also configure your wired Airzone Lite cable to act as wireless (the LED light will switch off after a few seconds).
ES
Note: To access the Lite Settings parameter from any Airzone Blueface thermostat, it is necessary to access the zone through the Zone
Navigation parameter.
EN
WARNINGS AND ERRORS
FR
Airzone Blueface thermostat displays all the system warnings in your screensaver. Besides, if there is any error, it will be
displayed on the screensaver, on the main screen and on "Errors", in user settings.
IT
PT
Warnings
Anti-freezing. It will be only displayed when it is activated. (See Section Zone
DE
Settings).
Window. It indicates the air conditioning of the zone has been deactivated due to
open window. Only available if the window contact of the system is activated.
Low battery Lite. Low battery warning. Informs about the involved zone when the
icon is pressed.
Incidents
If any of these errors occurs, please contact with your installer.
Error 1. Communication error with the main control board.
Error 5. Temperature sensor is opened.
Error 6. Temperature sensor is short circuited.
Error 8. Lite thermostat not found.
Error 9. Communication error between the communications gateway and the system.
Error 11. Communication error between the communications gateway and the indoor unit.
Error 13. Communication error between the main control board and the control module of radiant elements.
Error 14. Communication error with theexpansion module.
AC unit error. Error in the AC unit.