Honeywell CT50 Serie Manual De Uso página 3

Ocultar thumbs Ver también para CT50 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Mount thermostat base
1. Drill holes at pencil-marked
locations (3/16" holes for
drywall, 7/32" holes for
plaster).
2. Use hammer to tap anchors
into holes until flush with wall.
3. Pull wires through thermostat
base and insert screws.
Check level if desired, then
tighten screws.
Connect wires
1. Match each labeled wire with same
letter on terminal.
2. Use a screwdriver to loosen screw
terminals, insert bare wires beneath
screws, then tighten screws.
3. Push any excess wire back into the
wall opening.
Labels don't match?
If labels do not match letters on
thermostat, see table below.
Existing wires Connect to:
R • RH • 4 • V
Rc
O
B
G • F
W • W1 • H
Y • Y1 • M
C • X • B
English:
Terminal "R"
[1]
Terminal "Rc" [1]
Terminal "O"
[2]
Terminal "B"
[2]
Terminal "G"
Terminal "W"
Terminal "Y"
Do not use
[3]
Page 1
• Français :
CT50/CT53/CT54
Wiring CT50/CT53/CT54
• 2-wire heat-only system: Connect one
wire to R terminal, one wire to W terminal.
Wiring CT51/CT55
[1] If wires will be connected to both R and Rc
terminals, remove the metal jumper.
[2] Do not connect both O and B if you have a
heat pump. Connect only the O wire. Wrap B
wire with electrical tape and do not use.
[3] Do not use C, X or B. Wrap bare end of wire
with electrical tape.
3
Page 6
• Español:
CT51/CT55
69-2040EFS—01
Página 11
M23791
M23792

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ct50Ct51Ct53Ct54Ct55

Tabla de contenido