5.6.
Calendar override setting
The controller needs a method to set days between regeneration for regulatory requirements and in cases when the flow sensor
has failed.
A
Press and hold
and
→ The programmed calendar override is displayed.
B
Press
to increases value.
→ Range from 0 through 30;
0 = Disabled;
0.3 = Regeneration every 8 hours : at 2, 10 and 18 hours;
0.5 = Regeneration every 12 hours : at 2 and 14 hours;
1 - 30 = Regeneration every X days (every 3 days in this example).
5.7.
System selection
The controller has four system settings available. The system selections accommodate multiple tank sizes and various
feedwater conditions.
System selection:
A
Press and hold
and
→ A small "u" will be displayed in the left digit.
→ The right digit will display the current system setting.
B
Press
until desired system setting appears then release.
→ The displayed system setting will be stored in flash memory when the controller
exits programming after 5 seconds.
6 .
Startup
1.
Fill the brine tank in the cabinet with salt.
2.
Adjust the safety brine valve in the brine well to make sure the overflow elbow is installed above the float level.
3.
After the softener has been running a few minutes in service, proceed to hardness test on outlet water to make sure the
water is treated as per requirements, and eventually adjust the mixing device accordingly.
NOTE
Pentair advise to set a residual hardness between 50 and 100 mg/L of CaC0
7 .
Operation
7.1.
Display
7.1.1. During operation
• The current time in 24 hours is displayed on 2 digits
(minutes are not displayed).
• The flow indicator blinks ON and OFF when water is flowing.
Ref. MKT-UG-045 / A - 13.03.2020
for 3 seconds.
simultaneously for 3 seconds.
User Guide Riversoft
.
3
17 / 132