Phototoxicity
Prolonged intense light exposure can damage the retina. Therefore, the use of the
device for ocular examination should not be unnecessarily prolonged, and the
brightness setting should not exceed what is needed to provide clear visualization of
the target structures.
The retinal exposure dose for a photochemical hazard is a product of the radiance
and the exposure time. If the value of radiance is halved, twice the time is needed to
reach the maximum exposure limit.
Do not obstruct the mains power switch or position the equipment where the
connection to the mains line can be accidentally disconnected.
The instrument is not suitable for use in the presence of a flammable anesthetic
mixture with air, oxygen, or nitrous oxide.
The RetinaStation has no special protection against the harmful ingress of water or
other liquids (classified IPX0). To avoid damaging the instrument and causing a
safety hazard, cleaning solutions, including water, should not be directly applied to
the instrument. Using a dampened cloth (without dripping) is a good method for
cleaning the exterior surface of the enclosure.
The patient cannot touch any electrical device that is not powered by RetinaStation
with any part of his or her body while being examined. In addition, the RetinaStation
operator must not attempt to touch the patient and any electrical device that is not
powered by RetinaStation while examining the patient. Failure to do so could result
in electrical shock to the patient and/or operator.
Do not connect any unspecified devices to the instrument. Doing so may result in
fire or electric shock. For details regarding purchasing accessories, please contact
your local Nikon representative or distributor.
Be sure to hold the bottom of the base when moving RetinaStation.
Do not operate the LCD monitor with wet hands or hard objects. Doing so many
damage the LCD monitor.
When adjusting the chin rest, be careful not to pinch the patient's hands.
This instrument must be installed on a stable table. Do not install this instrument in a
location that is unstable or exposed to vibration.
Federal law restricts the sale of this instrument to sale by or on the order of a
physician or practitioner (CFR 801.109(b)(1)).
When adjusting the Fundus camera head, be careful not to pinch hands with the
LCD monitor/touch panel or Base.
When adjusting the Fundus camera head, be careful not to bring the Ocular lens
into contact with the patient's face.