Maintenance Information • Operation - AERMEC GLL10M Manual De Instalación

Marco de impulsión y aspiración con aletas motorizadas
Ocultar thumbs Ver también para GLL10M:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

MAINTENANCE
- Routine maintenance is reduced to the periodical cleaning of the air filter. It must be extracted from the unit and then re-
mounted after it has been cleaned using a suction device.
Danger: interrupt the electric power supply if the unit must be accessed.
USE
An opening of 20° is recommended in heating mode and 10° in cooling mode. These positions are indicated with two raised
lines on the louvers (see figure).
Ventilation is allowed with the louvers closed.
Pressing the SWING button, the four defl ector louvres will turn around their own axis alternately from the 0° position (louvre
closed) to the 20° position (louvre open in heating position).
On reaching the desired position, press the SWING button again to block the louvres. On the contrary these will continue to
turn for a maximum time of 2 minutes and will then stop. In this case, to modify the position, act on the SWING button again.
WARNING: Do not try to act manually on the defl ector louvres of the GLL M grid unit so as not to jeopardise functioning.
Position of the louvers in heating mode opening 20°.
Position of the louvers in cooling mode opening 10°.
Ventilation is allowed with the louvers closed.
10

Publicidad

Tabla de contenido
loading

Tabla de contenido