INSTALLATION
Electrical Connections
!
Warning:
Electrical and grounding connections
must comply with all applicable
Electrical Codes.
!
Warning:
When working on the dishwasher,
disconnect the electric service and
place a tag at the disconnect switch
to indicate work is being done on
that circuit.
1. A qualified electrician must compare the
electrical power supply with the machine
electrical specifications before connecting
to the incoming service through a fused
disconnect switch.
Refer to Fig. 4
Electrical knock-out
right rear corner
Esquina posterior
derecha de salida del
servicio eléctrico
Figure 4
Electrical Connection Location
Ubicación de la conexión eléctrica
2. A knock-out is provided at the lower right rear
corner for the electrical service connection.
A fused disconnect switch or circuit breaker
(supplied by others) is required to protect
the power supply circuit.
INSTALACIÓN
(Cont.)
Conexiones eléctricas
!
!
Advertencia:
Cuando esté trabajando en el
lavavajillas, desconecte el suministro
eléctrico y coloque una etiqueta en el
interruptor de desconexión que indique
que se está trabajando en ese circuito
.
1. Un electricista capacitado debe comparar
el suministro de energía eléctrica con las
especificaciones eléctricas de la máquina
antes de conectar el suministro de energía al
interruptor de desconexión equipado
con fusibles.
Consulte la figura 4
2. Existe una salida en la esquina inferior derecha
del lado posterior para la conexión del servicio
eléctrico. Se requiere contar con un interruptor
de desconexión equipado con fusibles o un
disyuntor (suministrado por otros proveedores)
para proteger el circuito de suministro de
energía.
(cont.)
Advertencia:
Las conexiones eléctricas y a tierra
deben cumplir con todas las normas
de electricidad que correspondan.
INSTALLATION