PrIncIPal oF oPeraTIon

This unit is designed for use as a vacuum brake or
clutch bleeder, or fluid evacuator. It utilizes com-
pressed air between 60 psi (4.1 bar) and 150 psi
(10.3 bar), and a venturi system, to build vacuum
in the reservoir. The hose extending from the lid
and ending in the L-shaped bleed screw adapter,
allows the vacuum to be used to drain brake fluid
from a hydraulic system such as the brake or
clutch systems on an automobile.

Important Precautions

• Always read carefully and understand instruc-
tions prior to using this equipment
• Brake fluid is highly corrosive. Wear gloves and
approved safety goggles at all times, and pre-
vent contact of the fluid with painted surfaces.
• Consult and follow the vehicle manufacturer's
recommended procedures when servicing any
hydraulic system.
• Do not use this unit with flammable liquids or
with fluids at temperatures above 175° Fahren-
heit (80° Celsius).
• Properly dispose of old fluids, and replenish hy-
draulic systems with new brake fluid from freshly
opened containers.
• Do not attempt to pressurize the bleeder/evacu-
ator. It is designed for vacuum use only.
• This unit is equipped with an automatic shut-off
device that will prevent fluid from entering the
compressed air stream and ejecting through
the exhaust. However, if the unit is continuously
operated when the reservoir is full, residual pres-
sure will allow the reservoir to completely fill with
fluid, creating the potential for spillage when the
lid is removed. To prevent this situation, empty
or turn the unit off prior to filling the reservoir
completely full.