DESULPHATION
1
1
15.8V
12V
WET
15.8V
12V
AGM
19.2V
16V
WET
19.6V
16V
AGM
Limit:
Max 4h
20016605A MURS 7.0, Manual, Print file 007.indd 9
SOFT START
BULK
2
3
7A until 12.6V
Increasing voltage
to 14.4V.
7A
7A until 12.6V
Increasing voltage
to 14.7V.
7A
5A until 16.8V
Increasing voltage
to 19.2V.
5A
5A until 16.8V
Increasing voltage
to 19.6V.
5A
Max 4h
Max 30h
ABSORPTION
ANALYSE
4
5
Declining current
Checks if voltage
14.4V
drops to 12V
Declining current
Checks if voltage
14.7V
drops to 12V
Declining current
Checks if voltage
19.2V
drops to 16V
Declining current
Checks if voltage
19.6V
drops to 16V
Max 8h
3 minutes
FLOAT
PULSE
6
7
13.6V
12.9V‒14.4V
7A
7‒2A
13.6V
12.9V‒14.7V
7A
7‒2A
18.1V
17.2V‒19.2V
5A
5‒2A
18.1V
17.2V‒19.6V
5‒2A
5A
10 days
Charge cycle restarts
Charge cycle restarts
if voltage drops
if voltage drops