Connecting the drain hose

We advise against the use of hose extensions; in
case of absolute need, the extension must have the
same diameter as the original hose and must not
exceed 150 cm in length.

Electric connection

Before plugging the appliance into the mains
socket, make sure that:
• the socket is earthed and in compliance with the
applicable law;
• the socket is able to sustain the appliance's
maximum power load indicated in the Technical
details table (on the right);
• the supply voltage is included within the values i
ndicated on the Technical details table
(on the right);
• the socket is compatible with the washing
machine's plug. If this is not the case, replace
the socket or the plug.

The washing machine should not be installed in an
outdoor environment, not even when the area is
sheltered, because it may be very dangerous to
leave it exposed to rain and thunderstorms.

When the washing machine is installed, the mains
socket must be within easy reach.
Connect the drain hose,
without bending it, to a
draining duct or a wall
drain situated between
65 and 100 cm from
the floor;
alternatively, place it
over the edge of a
basin, sink or tub,
fastening the duct
supplied to the tap (see
figure). The free end of
the hose should not be
underwater.

Do not use extensions or multiple sockets.

The power supply cable must never be bent or
dangerously compressed.

The power supply cable must only be replaced by
an authorised serviceman.
Warning! The company denies all liability if and when
these norms are not respected.

The first wash cycle

Once the appliance has been installed, and before
you use it for the first time, run a wash cycle with
detergent and no laundry, setting the 90°C
programme without a pre-wash cycle.

Technical details

M odel
W IXL 10 5
5 9.5 cm w ide
Dim e nsions
8 5 cm h ig h
5 6.5 cm deep
Capacity
from 1 to 6 kg
Electric
vo ltage 22 0 /2 3 0 Volts 5 0 Hz
conne ctions
max imu m abs o rbed pow er 1 85 0 W
maximu m pres s u re 1 MPa (1 0 bar)
Water
min imu m pres s u re 0.0 5 M Pa (0.5 bar)
conne ctions
dru m capacity 52 litres
Spin spe ed
u p to 10 0 0 rpm
Control
program m es
pro g ramme 2 ; temperatu re 6 0°C;
according to
ru n w ith a lo ad o f 6 kg.
IEC456 dire ctive
T h is applian ce is co mplian t w ith th e
follo w in g Eu ro pean Comm u n ity
D irectives :
- 7 3/2 3/CEE o f 19 /0 2/7 3 (L ow
Vo ltage) an d s u bs equ en t am en dmen ts
- 8 9/3 36 /CEE o f 0 3 /05 /89
(Electromagn etic Co mpatibility) an d
s u bs equ en t amen dmen ts
- 2 00 2/9 6 /CE