Four-Wire Plug - Alliance Laundry Systems SWD441C Manual De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

3. Use the three screws from the envelope located in
the cylinder to attach the power cord wires to the
terminal block.
1
1
"L1" Terminal
2
Neutral Terminal
3
"L2" Terminal
Figure 29
4. Tighten all screws and reinstall access cover
removed in step 1.
IMPORTANT: Failure to tighten these screws
firmly may result in wire failure at the terminal
block.
5. Secure the strain relief to the power cord, or
wires, where they enter the dryer cabinet.
6. Check the continuity of the ground connection
before plugging the cord into an outlet. Use an
acceptable indicating device connected to the
center grounding pin of the plug and the green
screw on the back of cabinet.
7. Reinstall access cover and screw.
801504
2
3
D286I
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Four-Wire Plug

1
1
Typical Four-Wire Receptacle
2
Power Cord – Not supplied with dryer
(Four-Wire)
3
Strain Relief Nut
4
Strain Relief
Figure 30
1. Remove access cover from rear of dryer.
Figure 31
Installation
2
4
3
D815I
D695I
23

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido